Opens in a new tab

Fire Alarms

Whether you require a single alarm or a complete security system for a large industrial unit we can design, supply, install and then maintain your chosen system. Making homes and businesses protected and safer for all our customers.

Fire alarm system
Dahua logo
Visonic logo
Sony logo
DualCom logo
Emizon logo
Hikvision logo

Fire Alarm Installation and Servicing for Businesses in Cardiff, Bridgend and South Wales

If you own or run a commercial premises you are legally responsible for having a suitable fire detection system and keeping it maintained. VOG Fire & Security designs, installs, tests and services fire alarm systems to BS 5839-1 for offices, shops, warehouses, schools, care homes, HMOs and blocks of flats across the Vale of Glamorgan and South Wales, and has done for over [20/35] years. Call 01446 739586 to book a free site survey.

Book a fire alarm survey

Conventional or addressable fire alarm?

Conventional panels split the building into zones and tell you a detector in a zone has activated. Addressable panels tell you exactly which device activated, which matters in larger or multi floor buildings where finding the source quickly saves time and avoids full evacuations for a burnt toast alarm. Wireless (radio) fire alarm systems avoid cabling in listed buildings, occupied premises or where disruption must be kept to a minimum. VOG installs all three.

Safety inspector testing wall-mounted fire alarm with tablet
Book a fire alarm survey
Fire alarm activation

What fire alarm system does your premises need?

That depends on your fire risk assessment, which sets the category of system the building needs. Fire alarm systems for non domestic buildings are designed to British Standard BS 5839-1 and fall into these categories:

  • Category M: manual only. Break glass call points and sounders, no automatic detection. The minimum for small, low risk premises.
  • Category L (life protection): automatic detection to protect people. L5 covers a specific risk, L4 covers escape routes, L3 adds rooms opening onto escape routes, L2 adds high risk areas, and L1 covers the whole building.
  • Category P (property protection): automatic detection designed to protect the building and contents, often required by insurers. P2 covers defined areas, P1 covers the whole building.

Most small offices, shops and workshops need an L4 or L3 system. Care homes, hotels, HMOs and buildings where people sleep usually need L2 or L1. The survey confirms which applies to you.

Book a fire alarm survey
Engineer inspecting diesel fire pump controller with clipboard

What are your legal obligations for a commercial fire alarm?

Under the Regulatory Reform (Fire Safety) Order 2005, which applies in Wales, the responsible person for the premises must carry out a fire risk assessment, provide an appropriate fire detection and warning system, and maintain it in working order. In practice that means:

  • A weekly test of a different call point, recorded in the fire log book
  • Inspection and servicing by a competent person at least every six months, in line with BS 5839-1
  • Keeping the log book up to date with tests, faults, false alarms and servicing visits
  • Acting on any recommendations from the service engineer

Failure to comply can lead to enforcement notices, prosecution and invalidated insurance.

How often does a fire alarm need servicing?

Every six months. BS 5839-1 recommends that the interval between servicing visits does not exceed six months, so the usual arrangement is two visits a year. Each visit checks the panel, batteries and power supply, tests a proportion of detectors and call points so that all are tested over the year, checks sounders and any links to a monitoring centre, and records everything in your log book with a certificate. VOG takes on servicing of existing systems as well as systems it has installed, across Cardiff, Barry, Bridgend, Penarth, Cowbridge, Llantwit Major and Caerphilly.

Can your fire alarm be monitored?

Yes. A monitored fire alarm sends a signal to an alarm receiving centre when it activates, so the fire service can be called even when the building is empty. This is worth having for any premises left unoccupied overnight, and insurers often require it for higher value stock or equipment. VOG fits dual path signalling so the system still reports if the phone line or broadband goes down.

What affects the cost of a commercial fire alarm system?

The category of system your risk assessment requires, the size and layout of the building, whether it is conventional, addressable or wireless, the number of detectors, call points and sounders, and whether monitoring is needed. A free survey gives you a design and a written quote. VOG will beat any like for like written quotation from another accredited installer, and every fire alarm comes with a two year warranty.

How is a fire alarm installed in an occupied business?

Around your working hours where needed. The engineers survey the building, agree a design with you, and schedule the installation to keep disruption low. Cabling is run neatly and fire rated cable is used throughout. On completion the system is fully tested and commissioned, you receive a certificate and log book, and staff are shown how to use the panel, silence and reset the alarm and carry out the weekly test.

Where does VOG install and service fire alarms?

Across Cardiff, Barry, Bridgend, Penarth, Cowbridge, Llantwit Major, Caerphilly and the rest of the Vale of Glamorgan and South Wales.

Book a fire alarm survey
Hand pressing a red fire alarm call point

Servicing the Vale of Glamorgan, Cardiff and beyond

Get Started
Map of Barry service area
Map of Cardiff service area
Map of Cowbridge service area
Map of Bridgend service area
Map of Llantwit Major service area
Map of Caerphilly service area
Map of Cowbridge service area

Customer Testimonials

Find Out More

Fire Alarms FAQs

Almost always, yes. The Fire Safety Order requires an appropriate means of detecting and warning of fire in all non domestic premises. In a very small single room unit that may be a manual system, but your fire risk assessment decides.

Smoke alarms are self contained units for houses. A fire alarm system has a control panel, detectors, call points and sounders, and is what commercial buildings, HMOs and flats with communal areas need. See the smoke alarms page if you are a landlord with a single let house.

A competent person, meaning someone with the training and experience to work to BS 5839-1. VOG is SSAIB approved and provides a certificate after every service visit.

Cooking, steam, dust from building work and poorly sited detectors. An addressable system, the right detector type for each area and regular servicing cut false alarms significantly.

Yes. A log book is supplied with every installation and completed at every service visit.

Yes. The fire alarm can release access controlled doors on activation and is normally installed alongside emergency lighting so the whole life safety system is serviced together.

Get a free Fire Alarms survey. Call 01446 739586 or send a message and an engineer will visit at a time that suits you.